High Voltage HV Series
Available Enclosure Sizes: 1x1 Connection Series
Enclosure Size Max kV Max Amp T6/t5
-241206 1.5 315
-242006 1.5 315
-201206 2.5 250
-161606 2.5 200
-241606 2.5 315
-301606 2.5 400
-202006 2.5 250
-201407 2.5 250
-251807 2.5 315
-302207 2.5 400
-362507 2.5 400
-201610 6.6 250
-302010 8 400
-242010 8 315
-302410 8 400
-242410 8 315
-362410 8 400
-362510 8 500
-603610 8 500
-603616 8 500
Available Enclosure Sizes: 2x2 Connection Series
(2 parallel, unshielded cables)
Enclosure Size Max Voltage Max Amp T6 Max amp T5
 -202008 2kV 500 500
 -242008 2kV 630 630
 -242408 2kV 630 630
 -202010 2kV 500 500
 -242010 2kV 630 630
 -242410 2kV 630 630
 -302010 2kV 650 800
 -302410 2kV 650 800
 -362410 2kV 650 800
 -362510 2kV 650 1000
 -603610 2kV 650 1000
Construction:
- Available in (3) Materials: SS304, SS316L, Powder Coated (ASA61 Grey) Steel
- Folded Lip around the Door Opening to provide complete and maximum gasket seal
- Continuously Welded and Ground Smooth Seams
- Silicone Strip Gasket
- Welded on External Mounting Mounting Feet with 5/16” Clearance Holes/Slot
- External Door Clamps
- Continuous Piano Type Hinge with Removable SS Hinge Pin
- Ground Studs on Box and Cover
- Internal/External Earthing Lugs
- Universal Rail Mounting System
- Padlock Hasp & Staple for Padlocking
Certifications:
- DEMKO: EEx e II T6 (T5 Tamb+55C) Assemblies<650Amp EEx e II T5 Tamb+55C Assemblies >651Amps
- ATEX: (EX)0539 (CE)II 2 GD
- UL/cUL: AEx e II T6 (T5 Tamb+55C) Assemblies <650AmpsAEx e II T5 Tamb+55C Assemblies >651Amps
Ex e II T6 (T5 Tamb+55C) Assemblies <650Amps
Ex e II T5 Tamb+55C Assemblies >651Amps
Class II Division 2
UL50: NEMA 4, 4X (HV4X & HV4X6 series only), 12 & 13
IEC60529: IP66
Gland Plates:
These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site.
Add the following Suffixes:
A: Gland Plate installed on top of box.
B: Gland Plate installed on bottom of box.
C: Gland Plate installed on left of box.
D: Gland Plate installed on right of box.
For multiple gland plates omit dashes (i.e. HV4X-201407-ABCD)
Conduit/Cable Entries:
Entries can be provided per a customer supplied sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of the Increased Safety Section in the CENELEC Product Catalog. Note: This information is important and could affect the size of the enclosure you selected.
|
|
| UPCOMING EVENTS |
Offshore Technology Conference 2008 May 5 - 8
Reliant Center
Houston, TX... |
ISA Expo 2008
October 14 - 16
Reliant Center
Houst... |
| more |
|
|
| FEATURED PRODUCTS |
THERMAL MANAGEMENT SYSTEM FOR ENCLOSURES Cleveland, OH - Adalet announces a complete line o... more |
SS Window Kit Adalet stainless steel enclosures can now be order... more |
|
|